{"id":21249,"date":"2026-05-14T16:12:27","date_gmt":"2026-05-14T14:12:27","guid":{"rendered":"https:\/\/tml.lt\/en\/?page_id=21249"},"modified":"2026-05-14T16:17:23","modified_gmt":"2026-05-14T14:17:23","slug":"cable-printer-big-wires-id","status":"publish","type":"page","link":"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/","title":{"rendered":"Marking Large-Diameter Wires with Cable Printers"},"content":{"rendered":"<div class=\"alignright\"><img decoding=\"async\" loading=\"lazy\" alt=\"Marking large-diameter wires with cable printers\" src=\"\/ru\/wp-content\/uploads\/2026\/05\/supvan_tp86_bucket-2-1-300x150.webp\" style=\"width:100%;height:auto;max-width:300px;max-height:150px;\"><\/div>\n<p>Cable printers can print markings on tubes with diameters <a href=\"#less6mm\"><em>up to 6 mm<\/em><\/a>.<\/p>\n<p>How to mark wires with diameters <a href=\"#more6mm\"><em>greater than 6 mm<\/em><\/a>?<\/p>\n<p>What is the difference between marking methods for an already <a href=\"#after\">connected wire<\/a> and a <a href=\"#before\">non-connected wire<\/a>?<\/p>\n<div class=\"blk100\">\n<div class=\"alignleft\"><img decoding=\"async\" loading=\"lazy\" src=\"\/ru\/wp-content\/uploads\/2014\/07\/kabel-marker-nekleevaya-vstavka-150x150.jpg\" alt=\"marking wires thicker than 6 mm\" width=\"150\" height=\"150\"><\/div>\n<h4 id=\"more6mm\">Diameter of marked wires <span class=\"txtred\">GREATER THAN 6 mm<\/span><\/h4>\n<p>The solution is the use of <strong>external marking carriers<\/strong> into which a plastic insert or <a href=\"https:\/\/tml.lt\/en\/encyclopedia\/label\/\" target=\"_self\" title=\"Label is a functional part of a self-adhesive material, consisting of a face material and an adhesive. Most often it has a rectangular shape, but any shape can be cut.\" class=\"encyclopedia\">label<\/a> is placed. The marker is not attached directly to the wire but is placed in an additional carrier &mdash; a transparent container or sleeve. This also provides additional protection of the marking from damage. Carriers are especially convenient when the wire marking needs to be changed.<\/p>\n<p>Let us consider this using the <a href=\"\/en\/product\/cable-id-printer-supvan-tp-86e\/\">Supvan Tp-86e<\/a> printer as an example.<\/p>\n<\/div>\n<div class=\"blk50\">\n<div>\n<img decoding=\"async\" loading=\"lazy\" src=\"\/ru\/wp-content\/uploads\/2026\/04\/tml-pt_marker-insert-150x150.webp\" alt=\"wire marking before connection\" width=\"150\" height=\"150\">\n<h4 id=\"before\">If the holder is installed <span class=\"txtred\">BEFORE connecting<\/span> the wire<\/h4>\n<p>In this case, you can use <a href=\"\/en\/product\/tml-pt\/\">TML-PT sleeves<\/a> and the <a href=\"\/en\/product\/stripe-id-roll\/\">TML-SP4-12 insert<\/a>.<\/p>\n<p>The container length is 20 or 25 mm, and the wire diameters range from 0.25 to 35 mm.<\/p>\n<\/div>\n<div>\n<img decoding=\"async\" loading=\"lazy\" src=\"\/ru\/wp-content\/uploads\/2025\/11\/WKM-kontainer-150x150.webp\" alt=\"wire marking after connection\" width=\"150\" height=\"150\">\n<h4 id=\"after\">If the holder is installed <span class=\"txtred\">AFTER connecting<\/span> the wire<\/h4>\n<p>For marking already connected wires with diameters greater than 6 mm, <a href=\"\/en\/product-category\/wire-n-cable-marking\/transparent-marker-sleeve-fb-wkm\/\">transparent WKM containers<\/a> are used together with <a href=\"\/en\/product-category\/wire-n-cable-marking\/cable-id-printers\/flat-inserts\/\">plastic tapes<\/a> in 6 mm or 12 mm cassettes as the information carrier.<\/p>\n<p>WKM containers are available in three versions differing in holder size: 8&times;20 mm, 8&times;30 mm, and 18&times;43 mm.<\/p>\n<\/div>\n<\/div>\n<div class=\"blk100\">\n<div class=\"alignleft\"><img decoding=\"async\" loading=\"lazy\" src=\"\/ru\/wp-content\/uploads\/2024\/10\/termousad-markery-150x150.webp\" alt=\"wire marking up to 6 mm\" width=\"150\" height=\"150\"><\/div>\n<h4 id=\"less6mm\">Diameter of marked wires <span class=\"txtred\">LESS THAN 6 mm<\/span><\/h4>\n<p>When assembling electrical panels, where wires have diameters from 2 to 6 mm, we recommend an economical solution &mdash; marking with <a href=\"\/en\/product-category\/wire-n-cable-marking\/cable-id-printers\/pvc-tubes-economical-ib\/\">PVC tubes<\/a> or <a href=\"\/en\/product-category\/wire-n-cable-marking\/cable-id-printers\/heat-shrink-tubing-mt-ng-bg\/\">heat-shrink tubes<\/a>.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Cable printers can print markings on tubes with diameters up to 6 mm. How to mark wires with diameters greater than 6 mm? What is the difference between marking methods for an already connected wire and a non-connected wire? Diameter of marked wires GREATER THAN 6 mm The solution is the use of external marking [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":18917,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Marking Large-Diameter Wires with Cable Printers | TML<\/title>\n<meta name=\"description\" content=\"Marking Large-Diameter Wires with Cable Printers | TML\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Marking Large-Diameter Wires with Cable Printers | TML\" \/>\n<meta property=\"og:description\" content=\"Marking Large-Diameter Wires with Cable Printers | TML\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/\" \/>\n<meta property=\"og:site_name\" content=\"TML\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-14T14:17:23+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/\",\"url\":\"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/\",\"name\":\"Marking Large-Diameter Wires with Cable Printers | TML\",\"isPartOf\":{\"@id\":\"https:\/\/tml.lt\/en\/#website\"},\"datePublished\":\"2026-05-14T14:12:27+00:00\",\"dateModified\":\"2026-05-14T14:17:23+00:00\",\"description\":\"Marking Large-Diameter Wires with Cable Printers | TML\",\"breadcrumb\":{\"@id\":\"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u0413\u043b\u0430\u0432\u043d\u0430\u044f \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430\",\"item\":\"https:\/\/tml.lt\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solutions\",\"item\":\"https:\/\/tml.lt\/en\/solutions\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Electric power supply\",\"item\":\"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Marking Large-Diameter Wires with Cable Printers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/tml.lt\/en\/#website\",\"url\":\"https:\/\/tml.lt\/en\/\",\"name\":\"TML\",\"description\":\"UAB TML-LT\",\"publisher\":{\"@id\":\"https:\/\/tml.lt\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/tml.lt\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/tml.lt\/en\/#organization\",\"name\":\"TML\",\"url\":\"https:\/\/tml.lt\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/tml.lt\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/tml.lt\/en\/wp-content\/uploads\/2020\/09\/tml-logo-black-4.png\",\"contentUrl\":\"https:\/\/tml.lt\/en\/wp-content\/uploads\/2020\/09\/tml-logo-black-4.png\",\"width\":470,\"height\":110,\"caption\":\"TML\"},\"image\":{\"@id\":\"https:\/\/tml.lt\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Marking Large-Diameter Wires with Cable Printers | TML","description":"Marking Large-Diameter Wires with Cable Printers | TML","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/","og_locale":"en_US","og_type":"article","og_title":"Marking Large-Diameter Wires with Cable Printers | TML","og_description":"Marking Large-Diameter Wires with Cable Printers | TML","og_url":"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/","og_site_name":"TML","article_modified_time":"2026-05-14T14:17:23+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/","url":"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/","name":"Marking Large-Diameter Wires with Cable Printers | TML","isPartOf":{"@id":"https:\/\/tml.lt\/en\/#website"},"datePublished":"2026-05-14T14:12:27+00:00","dateModified":"2026-05-14T14:17:23+00:00","description":"Marking Large-Diameter Wires with Cable Printers | TML","breadcrumb":{"@id":"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/cable-printer-big-wires-id\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u0413\u043b\u0430\u0432\u043d\u0430\u044f \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430","item":"https:\/\/tml.lt\/en\/"},{"@type":"ListItem","position":2,"name":"Solutions","item":"https:\/\/tml.lt\/en\/solutions\/"},{"@type":"ListItem","position":3,"name":"Electric power supply","item":"https:\/\/tml.lt\/en\/solutions\/electric-power-supply\/"},{"@type":"ListItem","position":4,"name":"Marking Large-Diameter Wires with Cable Printers"}]},{"@type":"WebSite","@id":"https:\/\/tml.lt\/en\/#website","url":"https:\/\/tml.lt\/en\/","name":"TML","description":"UAB TML-LT","publisher":{"@id":"https:\/\/tml.lt\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tml.lt\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/tml.lt\/en\/#organization","name":"TML","url":"https:\/\/tml.lt\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/tml.lt\/en\/#\/schema\/logo\/image\/","url":"https:\/\/tml.lt\/en\/wp-content\/uploads\/2020\/09\/tml-logo-black-4.png","contentUrl":"https:\/\/tml.lt\/en\/wp-content\/uploads\/2020\/09\/tml-logo-black-4.png","width":470,"height":110,"caption":"TML"},"image":{"@id":"https:\/\/tml.lt\/en\/#\/schema\/logo\/image\/"}}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/tml.lt\/en\/wp-json\/wp\/v2\/pages\/21249"}],"collection":[{"href":"https:\/\/tml.lt\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tml.lt\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tml.lt\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tml.lt\/en\/wp-json\/wp\/v2\/comments?post=21249"}],"version-history":[{"count":0,"href":"https:\/\/tml.lt\/en\/wp-json\/wp\/v2\/pages\/21249\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/tml.lt\/en\/wp-json\/wp\/v2\/pages\/18917"}],"wp:attachment":[{"href":"https:\/\/tml.lt\/en\/wp-json\/wp\/v2\/media?parent=21249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}